ZY-BXR606C Energy Dispersive X-ray Fluorescence Spectrometer
1. Equipment features:
1. Adopting high-performance Si PIN detectors with American original electric cooling, high resolution, wide detection range, covering the basic requirements of RoHS, halogens, coatings, alloys (including precious metals), and various conventional material analysis.
2. Equipped with the most advanced international DPP digital multi-channel signal integration processor, it performs better than ordinary analog multi-channel signal processors, especially with better resolution at high counting rates (such as Hg and Cl). The data transmission speed of up to 80MHz makes analysis time shorter, measurement repeatability and long-term stability better.
3. Built in high-definition camera system, clear observation of samples, accurate positioning of sample testing area.
4. Equipped with the latest FP measurement software, integrating multiple spectrum processing algorithms and matrix correction algorithms, effectively reducing various interference peaks in instrument measurements, and achieving detection results for low content and trace elements
*Element analysis scope: Any element of sulfur (S) - uranium (U) can be analyzed for stainless steel, copper alloy, zinc alloy, tin lead alloy, precious metal analysis, etc. Quantitative testing of lead (Pb), mercury (Hg), cadmium (Cd), chromium (Cr), polybrominated biphenyls (PBB), and polybrominated biphenyl ethers (PBDE) in ROHS and halogens, as well as bromine (Br) and chlorine (Cl) in halogens. Can analyze up to 5 layers of plating, and can analyze up to 24 elements at once
*Technical parameters:
Lower detection limit: Pb/Cd/Cr/Hg/Br/Cl ≤ 2ppm
Test sample time: 50-300 seconds adjustable
Test content range: 1ppm -99.99%
The analysis and measurement have a wide dynamic range, ranging from 0.005 μ M to 50 μ M
Sample shape: any size, any irregular shape
Sample type: plastic/metal/film/powder/liquid
X-ray tube: tube voltage/0-50 kV tube current/maximum 1-1000 μ A. Maximum power: 50 W, filament voltage: 2.0V, filament current: 1.7 A, X-ray extraction angle: 12 ° Target material: tungsten target, beryllium window thickness: 400um, over temperature overload protection, automatically enters standby mode when not in operation to extend service life.
Illumination diameter: Collimator 8mm \ 2mm \ 1mm \ 0.5mm
Detector: Amptek Si PIN high sensitivity detector from the United States, with an optimal resolution of 149 ± 5eV.
Spellman high-voltage power supply in the United States: input voltage: DC+24V ± 10%, input current: 4.25A (maximum), output voltage: 0-50KV&1mA, maximum power: 50W, voltage adjustment rate: 0.01% (from no-load to full load), current adjustment rate: 0.01% (from no-load to full load), ripple voltage: under the premise of outputting rated voltage, the peak ripple voltage is 0.25% of the highest output voltage, and 8-hour stability: ≤ 0.05%.
Cooling system:
There are multiple heat dissipation holes in the front and back of the body for heat dissipation. There are three fans inside the body for air cooling, and the X-ray tubes are coated with high-temperature heat reducing resin and wrapped with heat dissipation fins. There is also one fan to blow and dissipate heat.
Radiation protection system:
The radiation protection design combines software and hardware, with triple processing: special radiation treatment of X-ray tubes, double-layer lead wrapping of sample covers, software radiation warning (if personnel accidentally open the sample chamber during instrument operation, the instrument will automatically shut down all power to ensure operator safety), obtaining a national radiation safety permit, and radiation dose lower than national standards.
Filter: Eight new types of filter automatic selection settings
Sample monitoring system:
A 30 times 15 million pixel color CCD camera can be used to observe the sample status in real-time on the software testing interface and adjust the sample position slightly before testing. After the sample testing is completed, the pattern is clearly displayed in the testing report.
Software system:
Quantitative analysis and calculation, using theoretical Alpha coefficient method (NBS-GSC method), integrated FP, and empirical coefficient method to accurately test RoHS halogen-free elements (Pb, Cd, Hg, Br, Cr, Cl). Multiple language operation interface, simple operation, one click design, can generate various personalized reports, and can automatically output report formats such as PDF and Excel.
Rated power: 0.35kW
Weight: 50Kg
External dimensions: 650 (W) x 450 (D) x 450 (H) mm
Sample chamber size: 350 (W) x 300 (D) x 150 (H) mm, large sample covers can be opened for testing.
*Standard configuration
A set of Amptek Si PIN detectors:
A side window X-ray tube with special radiation protection treatment for tungsten targets
A Spellman high-voltage power supply from the United States
Fully enclosed lead plate dual sample chamber
A high-precision CCD camera
A set of alpha coefficient method (NBS-GSC method), integrated FP, and empirical coefficient method software
One sample box, one sample cup for testing, and one roll of plastic film for testing
One EU PE # standard sample and one silver calibration standard sample
One set of instrument computer and one printer
Homepage   |    About   |    Advantage   |    Products   |    News   |    Support   |    Customer   |    Jobs   |    Contact   |    中文版
Add: A109# Diexinju Huanghe Road, Huanjiang Town, Dongguan City, Guangdong Province ,China.
Tel:+86-0769-82307158(总机) +86-769-88762868 Fax: +86-769-89768088 Email: zhuoyueyiqi@163.com
Copyright © Dongguan Zhuoyue Equipment Co.,Ltd. & KTS Equipment technology co.,ltd All Rights Reserved.
Web Design: CNBASHU

Zhuoyue Wechat