ZY-GC8100 Gas chromatograph (for EO residue)
I. Main performance characteristics:
1. 320 x 240 dot-matrix 5.7-inch large-screen LCD Chinese display, real-time display of each temperature and operating conditions, perfect online monitoring;
2. Power-on self-test, six-way independent temperature control (individual temperature control in vaporization chamber and capillary vaporization chamber), seven-step program temperature increase function;
3. Wide-range self-diagnostic function. When the instrument fails, it will automatically display the fault phenomenon, fault code, cause of the fault, help to find and resolve the fault as soon as possible, and ensure the best working condition of the laboratory
4. Over-temperature protection expansion function: If any channel exceeds the set temperature, the instrument will automatically power off and alarm;
5. Carrier gas cutoff and leak protection functions. When the carrier gas pressure is insufficient, the instrument automatically cuts off the power and stops heating, effectively protecting the column and the thermal conductivity detector from damage;
6. The door opening system after intelligent fuzzy control automatically tracks the temperature and dynamically adjusts the damper angle, enabling precise temperature control even near room temperature;
7. Equipped with packed-column head sampling, glass-lined sampling, capillary splitting and splitless sampling device with diaphragm cleaning function, and gas sampler can be installed;
8. High-precision dual-stable gas path, and up to four detectors can be installed at the same time;
9. Advanced gas path process, can realize the simultaneous use of hydrogen flame detector and thermal conductivity monitor;
10. Eight-way external event function supports multi-valve switching;
Second, the temperature control indicators:
1. Temperature control range: room temperature + 5 ℃ -400 ℃ increment 0.1 ℃
2. Temperature control accuracy: better than ± 0.1 ℃
3. Program temperature increase: constant temperature time between seven steps O ~ 999min
Increment 0.1min Temperature Increment 0.1 ℃
Heating rate: max. 40 ℃ / min below 200 ℃
200 ° C max. 20 ° C / min
Specifications:
1. Overall dimensions: 555 x 525 x 485 (mm)
2. Input power: AC220V ± 7% 50Hz 2KW
3. Machine weight: about 52kg
Fourth, the main configuration:
1 Gas chromatograph
(GC8100)
EO Residue 1. 5.7-inch large-screen LCD Chinese display, power-on self-test, wide-range self-diagnosis, door opening system after intelligent fuzzy control, over-temperature power-off protection, seventh-order range rise.
2. Configuration: host + hydrogen flame detector + capillary split / splitless injection system
3. Gas purifier, three independent valve switch control, gas purification device
2.Capillary column: ethylene oxide column 30m * 0.32mm * 0.5um
3 Standard sample: ethylene oxide standard, calibration sample concentration curve
4 Chromatography Workstation: Data Acquisition and Processing Software
5 Hydrogen generator: Hydrogen purity: 99.99
Output flow: 0-300 / min
Input pressure: 0-0.4MPa
Rated power: <150W
6 Air generator: Air purity: Oil-free third stage
Output flow: 0-3L / min
Input pressure: 0-0.4MPa (adjustable)
Rated power: 150W
7 Headspace sampler (including 100 sets of headspace bottles)
1. Sample heating range: 40 ℃ —200 ℃, temperature control accuracy: 1 ℃
2. Heating range of sample valve: 40 ℃ —200 ℃, temperature control accuracy: 1 ℃
3. Heating range of sample transfer tube: 40 ℃ —200 ℃, temperature control accuracy: 1 ℃
4. Sampling time: 0-20min
5. Pressing time: 0-30s
6. Volume of quantitative tube: 1ml
7. Headspace bottle specifications: 20ml (100 sets)
8. Samples can be heated at the same time: 9 positions
9. RSD: 1.5% (200ppm ethanol aqueous solution)
10. Power consumption: 220W
11. Overall dimensions: 500 × 180 × 400 (mm)
12. Net weight: about 15kg
8 High-purity nitrogen: cylinder + pressure reducing valve, purity 99.999% (customer-supplied)
9 Computer + printer: brand computer (customer-supplied)